ASTM D97 - ASTM D5853 - ASTM D5950 - ASTM D6074 - ASTM D6158 IP 15 - IP 441 ISO 3016 EN ISO 22995 Pour Point of petroleum products, crude oils, motor and engine oils, additives, lubricating oils, …
Click to enlarge
Home Linetronics Technologies Automatic Analysers NewLab 300 Pour Point
NewLab 200 CFPP Cold Filter Plugging Point
NewLab 200 CFPP Cold Filter Plugging Point
Back to products
NewLab 100 Cloud Point
NewLab 100 Cloud Point

NewLab 300 Pour Point

ASTM D97 – ASTM D5853 – ASTM D5950 – ASTM D6074 – ASTM D6158
IP 15 – IP 441
ISO 3016
EN ISO 22995

Pour Point of petroleum products, crude oils, motor and engine oils, additives, lubricating oils, …

Measuring Pour Point Principle

According to the methods, the sample is cooled down at a specified rate and, at the prescribed temperature intervals, the mechanical arm of the analyser lifts the test jar from the cooling jacket and tilts it in order to bring it in horizontal position to test the flow of the product. The sample movement is detected by the thermal probes (PT100 detection) placed above the sample surface which react if touched by the cooled sample.

Category: Automatic Analysers
Share:
  • Description
  • Envío y Entrega
Description
Measuring Pour Point Devices
  • Two PT100 detection probes placed on the surface of the product
  • Mechanical moving arm bringing the test jar in horizontal position

Measuring Temperature Probe
  • Platinum resistance PT100 class A

Measuring Parameters
  • Temperatures: in °C
  • Measuring range: -110°C … +100°C
  • Range of analysis: -90°C…+60°C (300/2-SA)
  • Resolution: 0.06 °C
  • Accuracy: ± 0.1 °C
  • Repeatability / Reproducibility: as per standards methods or better

Software Features

New LabLink software able to manage up to 6 analytical heads simultaneously (stand alone)

  • User friendly interface
  • All analytical parameters recorded
  • Customizable analysis parameters and methods
  • Customizable results report
  • Printable graphs and results
  • Self-identification of the typology of the analysers connected
The software includes:

Analysis Menu

  • Standard method as per ASTM / IP / ISO / EN / DIN… norms of reference:
    • (internal) with sample pre-heating
    • (external) without sample pre-heating
  • Optional methods:
    • T-sample – T-bath (Delta T constant)
    • cooling rate °C / h
    • selectable bath steps
    • fast bath
    • selectable tilt out test temperature
  • Audible alarm and displayed messages (at the end of the analysis and in case of errors and/or malfunctions)
Diagnostic Menu
  • Direct access to all analog, digital, inputs and outputs
  • Selectable value displaying: °C / Volt
Calibration Menu
  • Automatic calibration of each temperature probe
  • Last calibration date referred to each single probe displayed and relative data printable
  • Display of calibration diagram
  • Insertion of offset values
  • Standard and advanced calibration modes
Data Utilities
  • Fields for introduction of operator and product name
  • Archive viewer for files recall
  • All analysis stored in Excel® compatible format
  • Storage capacity for more than 60’000 analysis
  • LIMS compatible

Integrated Touch Screen Panel PC
  • TFT/LCD 12″
  • Resolution 1024 × 768, 16.2 M colours
  • 2 USB ports for connection to an external printer and/or external PC
  • Storage capacity for more than 60’000 analysis

Test Jar
  • Same dimensions and volume as described by the standard test methods
  • Product level mark
  • Small edge on the top in order to fix the glass cell to the analytical head

Cooling System

Integrated gas CFC free motor compressors:

  • Single stage (for temperatures up to -40°C / 1)
  • Double stage (for temperatures up to -80°C / 2)

Equipped with an automatic energy power save system. After 15 minutes from the end of the analysis the cooling system goes in stand-by mode.


Safety Devices
  • Pressure controller for 1st stage motor compressor
  • Pressure controller for 2nd stage motor compressor
  • Thermostat for 2nd stage activation
  • Thermo-switch for each cooling / heating jacket
  • Motor compressors equipped with internal overload devices

Electrical Supply
  • 220V ± 15% / 50 to 60 Hz
  • 115V ± 15% / 60 Hz

Cord Cable
  • 3 conductors flexible cable 2 m (7 feet) length with PVC sheath oil and heat resistant as per CENELEC directives

Ambient Temperature
  • Max 32 °C
  • H.R. 80%
Dimensions (cm) 1 test position 2 test position 3 test position 4 test position 6 test position
width 66 66 100 134 130
depth 60 60 60 60 75
height 80 80 80 80 170
Weight (kg)
single stage compressor 70 90 – – –
double stage compressor 80 100 130 160 280

NewLab 300 ST

  • Measuring range: -110°C …+100°C
  • Range of analysis: -110°C…+55°C
  • Resolution: 0.01 °C
  • Width: 34 cm
  • Depth: 60 cm
  • Height: 80 cm
  • Weight: 34 kg
NewLab 300 ST: Pour Point
Envío y Entrega
wd-ship-2

ENVÍO Y ENTREGA

Tenemos un enfoque centrado en el cliente y priorizamos los procesos de logística y transporte —y todos los necesarios— para aumentar la satisfacción de las empresas que compran nuestros productos.

Related products

Configuration Table

Automatic Analysers
Configuration Table PP CP CFPP FP CP+PP
Read more
NewLab 200 CFPP Cold Filter Plugging Point

NewLab 200 CFPP Cold Filter Plugging Point

Automatic Analysers
ASTM D6371 IP 309 EN 116 - EN 16329

Correlated:

IP 419
Cold Filter Plugging Point of diesel, biodiesel and heating fuels.
Measuring CFPP Principle
The sample is cooled down according to the methods and when the preselected temperature is reached a vacuum of 20 mBar is automatically applied to the sample. The product is sucked through the filter into the calibrated aspiration pipette. If the sample takes more than 60 seconds to reach the upper barrier detector (during the aspiration phase), or it fails to return completely into the test jar before that the product has cooled by a further 1°C, the Cold Filter Plugging Point is reached.
Read more
NewLab 100 Cloud Point

NewLab 100 Cloud Point

Automatic Analysers
ASTM D5771 DIN 51597 EN 23015 EN 590 IP 444 Correlated: ASTM D2500 - ASTM D5772 - ASTM D5773 IP 219 - IP 445 - IP 446 ISO 3015 JIS K2269
Cloud Point of petroleum products and biodiesel fuels
Read more
instrumed_white
  • Inicio
  • Nosotros
  • Productos
  • Contacto
INSTRUMED PANAMA 2023 CREADO POR PERFILES LATAM.
payments
  • Inicio
  • Productos
    • HORIBA
    • ThermoProbe
    • OMNITEK
  • Nosotros
  • Contacto
  • Compare
  • Login / Register
Shopping cart
close

Social Chat is free, download and try it now here!

English
Spanish